Precor EFX546 Manual de servicio Pagina 105

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 104
C546 Elliptical Fitness Crosstrainerl
Page 105
Procedure 7.28 - Replacing the Stub Tensioner
1. Set the on/off switch in the “off” position, then unplug the power cord from the wall outlet.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2. Remove the rear cover as described in Procedure 7.1.
3. Loosen the tension adjustment bolt to remove tension from the input belt. See Diagram
7.25.
Diagram 7.25 - Stub Tensioner Mounting
4. The early C546’s mounted the stub tensioner in a closed slot. If you have a unit with a
closed slot it is recommended that the slot be cut open with a hacksaw. Care must be taken
not to cut the belt or other adjacent parts. See Diagram 7.26.
Diagram 7.26 - Stub Tensioner Mounting Slot
Tension Adjustment Bolt
Stub Tensioner
Mounting Nut
Cut here
Vista de pagina 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 117 118

Comentarios a estos manuales

Sin comentarios