C546 Elliptical Fitness Crosstrainerl
Page 21
Procedure 5.1 - Measuring the Resistance of an Eddy Current
Magnet
Caution
Remove power from the EFX before you measure magnet resistance.
Procedure
1. Set the on/off switch in the “off” position, then unplug the power cord from the wall outlet.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
1. Remove the rear cover as described in Procedure 7.1.
2. Set the ohmmeter to a range that will conveniently read up to 125 Ω.
3. Disconnect the magnet wires. Measure the resistance between the two magnet wires.
Note:
The resistance of the magnets will be higher than optimum (90 - 110 Ω) when they are warm.
4. If the resistance measures significantly less than 90 Ω or significantly more than 110 Ω...
THEN... OTHERWISE...
Replace the magnet as described Reconnect the magnet wires, then
in Procedure 7.20. continue with the next step.
5. Re-install the rear cover as described in Procedure 7.1, then check the operation of the unit
as described in Section Four.
Comentarios a estos manuales